ProductsHome>Products>Composite Insulators>Composite Tube & Hollow Insulator
There
are two types of filament winding process in Wally Electric, one is wet winding, the other is dry winding with VPI(Vacuum Pressure Impregnation) process.
Wally Electric mainly focuses on friber reinforced epoxy resin vacuum casted composite functional components (insulators) and parts as below:
● 72.5~1100kV GIS Operating rods, Supporting insulators, Chamber insulators and other composite insulators. Tube or pipes produced by dry filament (or fabric) winding are bonded with metal armatures (inserts) and being used as operation rods, supporting insulators or chamber insulators for high voltage GIS, LTB, GCB, DTB...etc, application.;
● Silicon rubber coated wet winding tube used as hollow composite insulators, dry bushings, surge arrestors, capacitors for medium and high voltage power transformation, transmission, and distribution.
● For GIS capacitors shell and other high voltage (72.5~1100kV) insulators and functional components
application

典型材料特性
Typical Material Performance
|
Main Reinforcing Material |
Aramid-PET |
Aramid-PET |
Local E-glass |
Local Pure |
Local |
CN Standard |
Equal to |
|
|
(Process: Dry fabric winding) |
GB/T 5132.2-2009 |
IEC 61212-2:2006 |
||||||
|
Physical Properties |
||||||||
|
Fiber Content, by weight [w-%] |
-- |
-- |
55~57 |
-- |
-- |
GB/T
2577-2005 |
ISO
1172:1996 |
|
|
Density [g/ccm] |
1.30~1.33 |
1.31~1.34 |
1.70~1.75 |
1.30~1.33 |
1.31~1.34 |
GB/T 1033.1-2008 |
ISO 1183-1:2004,IDT |
|
|
Water Absorption [%] |
RT |
0.13~0.16 |
0.12~0.15 |
0.10~0.13 |
0.11~0.14 |
0.16~0.19 |
GB/T 1034-2008 |
ISO62:2008, IDT |
|
100°C |
0.15~0.18 |
0.14~0.17 |
0.10~0.13 |
0.12~0.15 |
0.16~0.21 |
|||
|
Tg Temperature [°C] |
≥120 |
≥120 |
≥120 |
≥120 |
≥120 |
GBT 19466.2-2004 |
ISO 11357-2:1999 |
|
|
Mechanical Properties |
||||||||
|
E-Modulus axial [MPa] |
≥23000 |
≥45000 |
≥25000 |
≥4500 |
≥24000 |
GB/T 1447-2005 |
ISO 527-4:1997 |
|
|
Tensile Strength, axial, FPF [MPa] |
≥500 |
≥700 |
≥250 |
≥120 |
≥550 |
|||
|
Tensile Strength, radial, FPF [MPa] |
≥100 |
≥50 |
≥150 |
≥100 |
≥250 |
|||
|
Bending Strength, axial, FPF [MPa] |
≥300 |
≥450 |
≥400 |
≥100 |
≥300 |
GB/T 9341-2008 |
ISO 178:2001,IDT |
|
|
Electrical Properties |
||||||||
|
Dielectrical Strength, axial, 50 Hz, 10 mm section [kV/mm] |
≥10 |
≥10 |
≥10 |
≥10 |
≥10 |
GB/T 1408.1-2006 |
IEC 60243-1:1998,IDT |
|
|
Dielectrical Strength, radial, 50 Hz, 3 mm Ring Section [kV/mm] |
≥22 |
≥20 |
≥20 |
≥22 |
≥18 |
|||
|
Surface resistance (1000V,20-25℃)Ω |
≥1×1014 |
≥3×1015 |
≥4.5×1015 |
≥7.5×1015 |
≥6×1014 |
GBT 1410-2006 |
IEC 60093-1980,IDT |
|
|
Volume resistance(ρ) (1000V,20-25℃)Ωcm |
≥5.5×1015 |
≥2×1017 |
≥1.5×1017 |
≥3.5×1016 |
≥1×1016 |
|||
|
Dielectrical Loss Factor Tanδ [%] |
0.61~0.65 |
0.65~0.70 |
0.31~0.35 |
0.35~0.40 |
0.75~0.80 |
GB/T 1409-2006 |
IEC 60250:1969,MOD |
|
|
Relative Permittivity |
3.4-3.6 |
3.4-3.7 |
4.0 - 4.5 |
3.2 - 3.3 |
3.1~3.5 |
|||
#CompositeTubeInsulator | #SiliconCoatedInsulator | #RubberCoatedInsulator | #CompositeHollowInsulators | #CompositeArrestors | #CompositeCapacitors | #ChamberInsulator | #SupportingInsulator | #GISInsulators | #OperatingRod | #OperationRod | #InsulationRod | #InsulatingRod | #DriveRod | #PullRod